INSTRUMENT PANEL
[ ] BAT MSTR switch -- ON; CPDS internal test starts
NOTE: Do not switch off CPDS during or after flight!
OVERHEAD PANEL
[ ] CDS/WARN UNIT TEST -- WARN UNIT (all warning lights must come on)
[ ] CDS/WARN UNIT TEST -- CPDS; Check display self test
[ ] Fuel XFER pumps sw
(AFT and FWD) -- ON; Check caution (F PMP AFT/FWD) off
[ ] Fuel XFER pumps sw
(AFT and FWD) -- OFF
[ ] Fuel PRIME pumps sw -- ON; Check caution on
[ ] A-COLL light -- ON
INSTUMENT PANEL
[ ] CAD fuel quantity -- Check
NOTE: Do not switch on FADEC before CPDS self test has been completed!
[ ] Rotor area -- CLEAR
[ ] ENG MAIN sw -- IDLE; Monitor:
N1 increase
TOT increase
Engine oil pressure increase
N2 and NRO increase
WHEN IDLE (N2>70%, IDLE Caution off) has been reached:
[ ] Both Fuel XFER pumps -- ON
[ ] Both Fuel PRIME pumps -- OFF
[ ] Avionic Master -- ON
[ ] Avionic -- CHECK ON
[ ] Instruments -- SET and CHECK
WHEN NORMAL SYMBOLOGY APPEARS ON FCDS:
[ ] Both ENG MAIN sw -- FLIGHT